Toner-cable XGDC One Port Horizontal Taps User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
969 Horsham Road
l
Horsham, Pennsylvania 19044 USA
l
Phone: 215-675-2053 Fax: 215-675-7543
l
Specifications Subject To Change Without Notice Rev 06-13 ©Toner Cable Equipment, Inc.
XGDC Series
1 GHZ Horizontal Taps
XGDC - Series One Tap Port Model
XGDC-TAP VALUE 7 9 12 16 20 24 27
5-550 MHz 6.5 9 12 16 20 24 27
ATTENUATION ±1.0 ±0.8 ±0.8 ±0.8 ±0.8 ±0.8 ±1.0
IN-TAP (dB) 550-1000 MHz 6.5 9 12 16 20 24 27
±1.2 ±1.2 ±1.2 ±1.2 ±1.2 ±1.2 ±1.2
INSERTION LOSS 5-15 MHz 2.5 1.4 0.9 0.8 0.7 0.7 0.7
IN-OUT 15-40 MHz 2.5 1.4 0.8 0.8 0.7 0.7 0.7
Maximum (dB) 40-550 MHz 2.5 1.4 0.8 0.8 0.7 0.7 0.7
550-1000 MHz 2.7 2.2 1.5 1.2 1.2 1.2 1.2
5-15 MHz 25 22 20 25 25 25 25
RETURN LOSS-IN 15-40 MHz 25 22 25 25 25 25 25
Minimum (dB) 40-550 MHz 20 20 20 20 20 20 20
550-1000 MHz 20 20 20 20 20 20 20
5-15 MHz 22 22 20 25 30 30 30
RETURN LOSS - OUT 15-40 MHz 22 22 28 30 30 30 30
Minimum (dB) 40-550 MHz 20 20 22 22 22 22 22
550-1000 MHz 18 20 20 20 20 20 20
XGDC2 - Series Two Tap Port Model
XGDC-TAP VALUE 7 9 12 16 20 24 27
5-15 MHz 6.5 9 12 16 20 24 27
ATTENUATION ±0.7 ±0.7 ±0.7 ±0.7 ±0.6 ±0.6 ±0.7
15-40 MHz 6.5 9 12 16 20 24 27
±0.7 ±0.7 ±0.5 ±0.7 ±0.6 ±0.6 ±0.6
40-550 MHz 6.5 9 12 16 20 24 27
±0.7 ±0.7 ±0.7 ±1.0 ±0.7 ±0.7 ±0.7
IN-TAP (dB) 550-1000 MHz 6.5 9 12 16 20 24 27
±1.5 ±1.5 ±1.5 ±1.2 ±1.2 ±1.2 ±1.2
INSERTION LOSS 5-15 MHz 3.6 2.5 1.4 1.3 0.7 0.7 0.7
IN-OUT 15-40 MHz 3.6 2.5 1.2 1.0 0.7 0.7 0.7
Maximum (dB) 40-550 MHz 3.6 2.5 1.4 1.0 0.7 0.7 0.7
550-1000 MHz 3.9 2.7 2.1 1.5 1.2 1.2 1.2
5-15 MHz 25 20 20 21 25 25 25
RETURN LOSS-IN 15-40 MHz 25 20 20 22 25 25 25
Minimum (dB) 40-550 MHz 22 20 20 22 22 22 25
550-1000 MHz 22 20 20 20 20 20 20
5-15 MHz 25 20 20 20 25 25 25
RETURN LOSS - OUT 15-40 MHz 30 25 25 30 30 30 30
Minimum (dB) 40-550 MHz 22 20 20 22 22 22 25
550-1000 MHz 22 20 20 20 20 20 22
XGDC3 - Series Three Tap Port Model
XGDC-TAP VALUE 7 9 12 16 20 24 27
5-15 MHz 6.5 9 12 16 20 24 27
ATTENUATION ±0.7 ±0.7 ±0.7 ±1.0 ±0.7 ±0.6 ±0.6
15-40 MHz 6.5 9 12 16 20 24 27
±0.7 ±0.7 ±0.7 ±0.7 ±0.7 ±0.6 ±0.6
40-550 MHz 6.5 9 12 16 20 24 27
±0.7 ±0.7 ±0.7 ±0.7 ±0.7 ±0.6 ±0.6
IN-TAP (dB) 550-1000 MHz 6.5 9 12 16 20 24 27
±0.7 ±0.7 ±1.2 ±1.2 ±1.2 ±1.2 ±1.2
INSERTION LOSS 5-15 MHz 7.0 3.6 2.4 1.2 0.8 0.8 0.8
IN-OUT 15-40 MHz 7.0 3.6 2.4 1.2 0.8 0.8 0.8
Maximum (dB) 40-550 MHz 7.0 3.6 2.4 1.2 0.8 0.8 0.8
550-1000 MHz 7.9 3.9 2.8 2.0 1.4 1.2 1.2
5-15 MHz 24 25 25 25 25 25 25
RETURN LOSS-IN 15-40 MHz 24 25 25 25 25 25 25
Minimum (dB) 40-550 MHz 22 22 22 22 22 22 22
550-1000 MHz 22 20 20 20 20 20 20
5-15 MHz 25 22 22 24 25 25 25
RETURN LOSS - OUT 15-40 MHz 30 28 25 25 28 28 28
Minimum (dB) 40-550 MHz 22 22 22 22 22 22 22
550-1000 MHz 22 20 20 20 20 20 20
Page view 1
1 2

Comments to this Manuals

No comments